English Русский Lietuvių
  • Aluminium doors and screenings
    • Fire resistant
    • Thermal insulated
    • Heavy person traffic
    • Folding and sliding
    • Windows
    • Façades
  • Steel doors and screenings
    • Fire and smoke resistant doors and screenings
    • Safety doors and windows
    • Doors and windows with thermal break
    • Doors and windows without thermal break
    • Doors, windows and curtain walls in stainless steel
  • Smoke and heat extraction systems (RWA)
    • Chain drives
    • Spindle drives
    • Electric linear drives
    • Opening and locking systems
    • Retractable arm drives
    • Emergency power supply units
  • Automatic door systems
    • Swing door systems
    • Sliding door systems
    • Revolving door systems
  • Door technology
    • Overhead door closers
    • Integrated door closers
    • Floor springs
    • Sliding door systems
    • Hold-open devices and mechanisms
  • Movable wall systems
    • Movable walls
    • Glass walls
    • Folding walls
OUR SERTIFICATES
        
    
       
  • ABOUT US
  • CONTACTS
  • OUR PROJECTS
Emergency power supply units

Central control units to control the individual components

GEZE Emergency power supply units

RWA BUS central control unit MBZ 300 is the new central control unit for smoke and heat extraction systems. The MBZ 300 units take over the supply, co-ordination and monitoring of all connected opening systems and components. They offer a high operational and service comfort.

The RWA emergency power supply unit E 260 N is the central control unit onto which all components are connected. It controls these components and provides them with power. In the event of a fire, it is activated via the automatic smoke detector, manual RWA switch or external alarms. Activation causes opening or closing of RWA openings, depending on the configuration of the central unit. Drives at the windows and smoke extraction openings can be controlled for regular ventilation operation via the ventilation switches. The RWA function is a higher level function than the ventilation function. 

GEZE RWA Emergency Power Supply Units E 260 N2/1-N12/2

Central control unit for many components

As a central control unit, all components are connected to the RWA emergency power supply unit. It controls the components and provides them with power. From the type designation of the RWA emergency power supply unit, it is possible to ascertain the maximum allowable output for the drives and the number of connectable ventilation groups.

Product features

  • Mains voltage 230 V AC 50 Hz
  • Output voltage 24 V (20-30 V) DC, residual ripple < 20%
  • Emergency power supply min. 72 h via 2 x 12 V lead batteries
  • All functions maintained even with emergency power supply (battery mode)
  • Smoke detector reset via RESET button
  • LED indicators for operating and fault indication
  • All emergency power supply units E 260 N are VdS-certified.


Connecting possibilities:

  • Up to four groups depending on the type of emergency power supply
  • Up to 10 smoke and heat detectors (RM1003/WM1005)
  • Up to 20 RWA switches FT 4- 24 V DC
  • Three vent switches with LED per group / any number without LED
  • Potential-free status contact: three contacts for alarm (horn), fault (warning light)

GEZE RWA Emergency Power Supply Units E 260 N32/2 - N32/8

Central control unit for a very large number of components

The RWA emergency power supply unit is the central control unit onto which all components are connected. It controls the components and provides them with power. From the type designation of the RWA emergency power supply unit, it is possible to ascertain the maximum allowable output for the drives and the number of connectable ventilation groups.  

Product features

  • Mains voltage 230 V AC 50 Hz
  • Output voltage 24 V (20-30V) DC, residual ripple < 20%
  • Emergency power supply min. 72 h via 2 x 12 V lead batteries
  • All functions maintained even with emergency power supply (battery mode)
  • Smoke detector reset via RESET button
  • LED indicators for operating and fault indication
  • All emergency power supply units E 260 N are VdS-certified

Connecting possibilities:

  • Up to eight drive groups
  • Up to 15 RWA switches FT 4-24 V DC
  • Up to 20 smoke and heat detectors (RM 1003/WM 1005)
  • Three vent switches with LED per group / any number without LED
  • Potential-free status contact: three contacts for alarm (horn), fault (warning light)

GEZE RWA Emergency Power Supply Unit MBZ 300

Central control unit for smoke and heat extraction

RWA BUS Central Control Unit MBZ 300 is a central control unit for smoke and heat extraction systems. The central unit takes over the supply, co-ordination and monitoring of all connected opening systems and components. The MBZ 300 offers a high operational and service comfort.

Product features
  • Convenient and simple expansion by clicking on additional module in a central control unit
  • Can be expanded as required to include alarm groups, ventilation groups and alarm lines
  • Mapping of complex alarm scenarios
  • Simple maintenance and installation thanks to the status display directly at the module
  • Wind-direction dependant control
  • Initial start up and configuration of the smoke and heat extraction central unit is possible without programming (quick and easy to adapt without PC)

 

  • The main components of the MBZ 300 in the switching cabinet
    • Power module
    • Control module
    • Drive module
    • Sensor module
    • Power expansion module
    • Switching power supply
    • Battery


 

 

© 2010-2012 UAB "MARX VILNIUS" - All rights reserved. Email info@marx.lt

Created by: UAB "NetForma"